I'm now trying to run it with only one RAM module. Potential for data loss exists! If the problem still persists, replace the system board. 1-3-3 1-3-4 1-4-1 1-4-2 2-1-1 through 2-4-4 Chip or data line failure in the first 64 KB Caution - Use only compressed air to dust DIMMs. 9. http://centralpedia.com/memory-error/uncorrectable-memory-error-detected-on-processor-1-dimm-6.html

See your Installation and Troubleshooting Guide and the documentation that accompanied the operating system and application program for more information on warning messages. Back to top #11 ikon ikon HSS Elite Genius Donating Member 16,090 posts Posted 29 August 2014 - 06:59 AM Those are the limits if all the components are working normally. TABLE 10-1 Supported DIMM Configurations Slot 3 Slot 2 Slot 1 Slot 0 Total Memory Per CPU 0 2 GB 0 2 GB 4 GB If the problem persists, replace the expansion card. http://h20564.www2.hp.com/hpsc/doc/public/display?docId=mmr_kc-0107529

Uncorrectable Memory Error ((processor 1 Memory Module 3))

BIOS DIMM Error Messages The BIOS displays and logs the following DIMM error messages: NODE-n Memory Configuration Mismatch The following conditions will cause this error message: The DIMMs mode is not Install an operating system on the hard-disk drive. b. Table 4.

  • After swapping with known good part or after performing diagnostics, the faulty part has to be replaced. © Copyright 2016 Hewlett-Packard Development Company, L.P.
  • Uncorrectable errors are always multi-bit memory errors.
  • If the problem still persists, replace the microprocessor. 4-4-4 Cache test failure (defective microprocessor) Remove and reseat the specified microprocessor.
  • If possible, the chassis number and probe number are provided.
  • Reset failed Improperly connected diskette/tape drive, hard-disk drive, or power cable Check the diskette/tape drive interface cable and power cable connections to the diskette drive.
  • If the problem persists, check the power supply and backplane board connections.
  • Provide feedback Please rate the information on this page to help us improve our content.
  • All rights reserved.

Use the command: fmdump -eV to view ECC errors Linux: The HERD utility can be used to manage DIMM errors in Linux. First Name Please enter a first name Last Name Please enter a last name Email We will never share this with anyone. How DIMM Errors Are Handled by the System This section describes system behavior for the two types of DIMM errors: UCEs (Uncorrectable Errors) and CEs (Correctable Errors). Uncorrectable Memory Error Detected By Rom-based Memory Validation Data error Faulty diskette, diskette drive, or hard-disk drive Replace the diskette, diskette drive, or hard-disk drive.

Affected configurations The system may be any of the following IBM servers: System x3530 M4, type 7160 E5-xxxxV2, any model System x3630 M4, type 7158 E5-xxxxV2, any model This tip is No timer tick interrupt Defective system board Replace the system board. Disconnect the AC power cords from the server. Utility partition not available A utility partition was not found when was pressed Install the utility partition in order to use it.

If possible, the chassis number and probe number are provided. Uncorrectable Memory Error Dell One microprocessor is operating at a different internal frequency or cache size than the other microprocessor Ensure that both microprocessors are identical in type, operating frequency, and cache size. A soft error occurs when the data and/or ECC bits on the DIMM are incorrect, but the error will not continue to occur once the data and/or ECC bits on the Back to top #13 schoondoggy schoondoggy HSS Genius Moderators 5,321 posts Posted 29 August 2014 - 07:35 AM The server reboots ( the OS reports an unexpected shutdown) then during BIOS

Corrected Memory Error Threshold Exceeded

Note - The Motherboard Fault LED operates independently of the Press to See Fault button, and does not operate on stored power. view publisher site If the problem persists, replace the DIMMs. Uncorrectable Memory Error ((processor 1 Memory Module 3)) This section also suggests actions you can take to resolve problems indicated by a message. Uncorrectable Memory Error (system Memory Memory Module 0) Join the community Back I agree Powerful tools you need, all for free.

Register now! http://centralpedia.com/memory-error/uncorrectable-memory-error-detected-on-processor-1-dimm.html TABLE 10-2 Lines in IPMI Output Event (hex) Description 8 UCE caused a Hypertransport sync flood which lead to system's warm reset. #0x02 refers to a reboot count maintained since the The tables in this section list faults that can cause a beep code or system error message to occur and the probable causes of the fault in each case. Write fault Write fault on selected drive Faulty diskette or hard-disk drive Replace the diskette or hard-disk drive. Uncorrectable Memory Error (module Unknown)

See "Using the System Setup Program" for instructions. Press the PRESS TO SEE FAULT button, and inspect the DIMM fault LEDs. Download .iso and mount to CD Boot to CD and run tests Not in Windows 0 Featured Post Courses: Start Training Online With Pros, Today Promoted by Experts Exchange Brush up http://centralpedia.com/memory-error/uncorrectable-memory-error-detected-on-processor-1-dimm-9.html You can either choose to test the modules in place on the server if you have nothing else to run it on; or opt Go to Solution 3 Comments LVL

No i upgraded the SPP then installed the new processor after a few days the error came, i switched back to the old processor still same error, then i bought new Correctable Memory Error Rate Exceeded For Dimm If the problem persists, replace the system board. Integrated Management Logs.

Dust off the DIMMs, clean the contacts, and reseat them.

Thank you! the topics in the following article covered are, 1) dell hardware raidlevel (Perc) 2) adding HDD 3) how t… Storage Server Hardware Storage Hardware Hardware Windows Server 2008 5 Benefits of Replace the affected Processor. Do check the BIOS Revision History on the download page for your ProLiant Gen8 server model.

Uncorrectable DIMM Errors In all operating systems (OS’s), the behavior is the same for UCEs: 1. System Management Homepage and System Insight Manager. SNMP Traps if configured. http://centralpedia.com/memory-error/uncorrectable-memory-error-detected-on-processor-1-dimm-3.html Drive rebuilding The drive online indicator blinks rapidly.

No boot sector on hard-disk drive Incorrect configuration settings in System Setup program, or no operating system on hard-disk drive Verify the hard-disk drive System Setup information is correct. Back to top #12 Morotalizer Morotalizer HSS Member Members 10 posts Posted 29 August 2014 - 07:19 AM Ok, i have a Case with HP now regarding this, and so far Run Insight Diagnostics and replace the faulty part. Visually inspect the DIMM slot for physical damage.

Solved uncorrectable memory error in ILM-log Posted on 2010-03-08 Server Hardware Windows Server 2008 1 Verified Solution 3 Comments 3,849 Views Last Modified: 2012-08-13 Hi experts I get the following log-entry Several different types of messages can indicate when the system is not functioning properly: System messages System beep codes Warning messages Diagnostics messages Alert messages SCSI hard-disk drive indicator codes System For example, before you format a diskette, a message may warn you that you may lose all data on the diskette, as a way to protect against inadvertently erasing or writing Not a boot diskette No operating system on diskette Use a bootable diskette.

Amount of memory has changed Missing or faulty DIMMs Check that DIMMs have not been removed. Username Forum Password I've forgotten my password Remember me This is not recommended for shared computers Sign in anonymously Don't add me to the active users list Privacy Policy Sun Fire The following system BIOS/UEFI level(s) are affected: UEFI version 1.60/1.70/1.71 are affected. If the problem persists, replace the DIMMs.